E01 series digital dosing pump (E01B uses a larger housing)
Digital Dosing Pump E01B – 90 to 200 L/h, up to 10 bar Price range: R96,662.96 through R103,715.63 incl. VAT
Back to products

Digital Dosing Pump E01C – 375 to 940 L/h, up to 10 bar

Price range: R128,607.38 through R165,945.00 incl. VAT

E01C series digital dosing pump: 3 models from 375 to 940 L/h at up to 10 bar. Vector-motor diaphragm drive, 1:15666 turn-down, ±1 % FS repeatability, local and remote control. Choose the model below — each has its own item code and price.

Flow / pressure

375 L/h · 10 bar

,

450 L/h · 6 bar

,

940 L/h · 4 bar

SKU: E01C Category: Tags: , ,
Description

Overview

The digital dosing pump E01C is the high-capacity series for bulk chemical feed. It covers 3 models, from 375 L/h · 10 bar to 940 L/h · 4 bar. First, a vector motor drives the diaphragm directly. As a result, you set the flow digitally anywhere in a 1:15666 range, and the pump repeats each dose to within ±1 % of full scale.

In addition, the E01C runs almost pulsation-free, because the motor controls the stroke speed rather than counting strokes. Slow modes at 50 % and 25 % speed therefore handle viscous chemicals up to 800 and 1500 cP.

The C series is the high-capacity range — 375 to 940 L/h with DN25 PVC connections and a 400 W drive — for bulk coagulant and disinfectant feeds. (Illustration shows the E01 series design; the E01C uses a larger housing.)

How you control the digital dosing pump E01C

You set everything on the pump itself: flow rate, pressure limits, wear-part monitoring, concentration proportioning and function switching. For plant control, the E01C offers RS485/Modbus, 4–20 mA, voltage and pulse inputs. Which of these are fitted depends on the electrical version, so we specify it with you.

Moreover, a sensor measures the conductivity inside the diaphragm and raises an alarm if the diaphragm cracks. Pipe-network pressure monitoring also flags blocked or leaking lines. Finally, a quick-release base takes the pump off its mount in seconds for service.

Key features

  • 3 models: 375 L/h · 10 bar, 450 L/h · 6 bar, 940 L/h · 4 bar
  • Vector-motor diaphragm drive — digital flow setting over a 1:6250 to 1:15666 turn-down range, low pulsation
  • Repeatability ±1 % FS; minimum flow 0.06 L/h
  • Local operation: flow setting, pressure and wear-part monitoring, concentration proportioning, function switching
  • External control: RS485/Modbus, 4–20 mA, voltage and pulse inputs (per electrical version)
  • Diaphragm crack detection (LDC conductivity monitoring) and pipe-network pressure monitoring with alarms
  • 50 % and 25 % slow modes for viscous liquids up to 1500 cP
  • PTFE/EPDM diaphragm, PP pump head, PVC check valves, pvc pipe connection DN25; 940-04: PVDF pump head
  • Quick-release base; 110 – 240 V AC 50 Hz supply; rated power 400 W
  • Options: pump heads in PVDF, PVC, CPVC, PP or stainless steel; EPDM, PTFE, FPM or FEPM gaskets; pressure and leakage sensors — specify when ordering

Digital dosing pump E01C — specifications by model

Performance

ModelE01C-375-10E01C-450-06E01C-940-04
Flow / pressure375 L/h · 10 bar450 L/h · 6 bar940 L/h · 4 bar
Turn-down ratio (setting range)1:62501:75001:15666
Maximum flow, standard mode (L/h)375450940
Maximum flow, 50 % slow mode (L/h)187.5225470
Maximum flow, 25 % slow mode (L/h)93.75112.5235
Minimum flow (L/h)0.060.060.06
Maximum operating (back) pressure (bar)1064
Repeatability (% FS)±1±1±1
Maximum suction lift, standard installation (m) ¹333
Minimum pressure difference inlet–outlet (bar) ²111
Maximum viscosity, standard mode (cP)100100100
Maximum viscosity, 50 % slow mode (cP)800800800
Maximum viscosity, 25 % slow mode (cP)150015001500

Materials, connections and power

ModelE01C-375-10E01C-450-06E01C-940-04
Inlet / outlet connectionPVC pipe, DN25PVC pipe, DN25PVC pipe, DN25
DiaphragmPTFE/EPDMPTFE/EPDMPTFE/EPDM
Pump headPPPPPVDF
Check valvesPVCPVCPVC
Liquid temperature (°C) ³0 – 450 – 450 – 45
Ambient temperature (°C)0 – 450 – 450 – 45
Maximum operating altitude (m)320032003200
Rated power (W)400400400
Power supply110 – 240 V AC, 50 Hz110 – 240 V AC, 50 Hz110 – 240 V AC, 50 Hz

Test conditions and options

¹ The supplier tested at an altitude below 100 m with pure water at 20 °C. ² A back-pressure valve on the outlet increases the pressure differential. ³ Optional flow components in other materials extend the medium temperature range — ask us.

Where to use the digital dosing pump E01C

The digital dosing pump E01C feeds coagulant, flocculant, hypochlorite, chlorine dioxide precursors, acid and caustic in water and wastewater plants. It also serves cooling-water and boiler-water treatment. In addition, mining, food, chemical and manufacturing plants use it for process dosing. For example, a pH or concentration control loop can drive the pump through its 4–20 mA or Modbus input.

Why buy dosing pumps from Hadron Group

Hadron Group designs, installs and services chemical dosing systems across South Africa and the SADC region. First, we size the pump to your duty point. Then we supply the suction and injection accessories, the spares and the chemicals it will dose. Finally, we commission it on site. Every model also carries its Hadron item code, so quotes, orders and spares always refer to the same pump.

Frequently asked questions

Which digital dosing pump E01C model do I choose?

Pick the flow and back pressure your duty point needs, with some margin. For example, choose 375 L/h · 10 bar for low-flow, high-pressure lines and 940 L/h · 4 bar for high-volume, low-pressure dosing. Each option carries its own item code and price.

How does the digital dosing pump E01C differ from a solenoid pump?

A solenoid pump doses in fixed strokes, so you turn it down by stroke frequency. The vector motor of the E01, however, controls the stroke speed itself. As a result, you get a far wider setting range, smoother output and precise dosing of viscous chemicals.

Can a PLC or controller drive it?

Yes. RS485/Modbus, 4–20 mA, voltage and pulse (water-meter contact) inputs are available, depending on the electrical version. In addition, the pump reports pressure, diaphragm and wear-part alarms.

Are spares and accessories available?

Yes — diaphragms, pump heads, check-valve sets and suction or injection lines. See dosing pump spares, or quote the model when you order.

Related: Digital Dosing Pump E01A · Digital Dosing Pump E01B · all dosing pumps · dosing pump spares.

Shipping & Delivery

Standard Shipment

3 - 5 working days

IMPORTS

6 - 8 Weeks