The AA29 Series Flame AAS

R275,000.00Each

The AA29 Series Flame Atomic Absorption Spectrometer (AAS) introduces a modern, compact design tailored for today’s laboratories. With fully PC-controlled functionality.

wws Sales Dept. / Pre-sale Questions Need Help? Contact Us via WhatsApp
SKU: HG_65943 Categories: ,
Description

The Advanced Features of the AA29 Series Flame AAS: A New Era in Elemental Analysis

Innovative Design and Configuration of the AA29 Series Flame AAS

The AA29 Series Flame Atomic Absorption Spectrometer (AAS) introduces a modern, compact design tailored for today’s laboratories. With fully PC-controlled functionality, the AA29 Series simplifies operation and data collection, allowing users to focus on obtaining accurate results. Its user-friendly interface enhances efficiency, making the analysis process more streamlined and less complex.

Key design features include:

  • Flexible configuration: Accommodates accessories to meet various analytical needs.
  • Application versatility: Suitable for petrochemistry, metallurgy, mining, geology, material analysis, food safety, and pharmacy.
  • Advanced optical system: Ensures stable readings and consistent results across a broad spectrum of analyses.

The AA29 Series provides precision and repeatability while minimizing interferences, setting a new benchmark in elemental analysis across scientific and industrial fields.

Key Safety Features and Performance Enhancements in the AA29 Series

The AA29 Series excels in safety and performance with several enhancements:

  1. Intelligent gas control module: Automatically adjusts gas flow and pressure, reducing risks and ensuring safe operations.
  2. Automatic pneumatic control: Regulates gas pressures for consistent, reliable results while adapting to various sample types.
  3. Total reflection optical system: Reduces energy loss, improving signal-to-noise ratio and sensitivity for detecting trace elements.

Additional safety measures include:

  • Deuterium lamp background correction: Minimizes reading interference.
  • Flame detection systems: Automatically shut down the device under unsafe conditions.
  • Pressure monitoring: Ensures safe operating parameters.

The modular design enables easy maintenance, reducing downtime, while the RGWIN AAS software simplifies operations, ensuring a seamless, high-performance user experience.

Flame AAS Specification

Model AA2914 AA2918 AA2928
Optical System Optical Type Single beam Single beam Double beam
Monochromator Czerny-Turner type with focal lengths at 350mm
Wavelength Range 190-900nm
Grating Holographic diffraction grating with 1800 lines/mm
Slits Automated slit selection 0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm
Wavelength Accuracy ±0.3 nm ±0.2 nm ±0.15 nm
Wavelength Repeatability ±0.1nm ±0.1nm ±0.05nm
Lamp Holder Automated 4-lamp turret Automated 8-lamp turret
Detector Wide range UV sensitive photomultiplier tube
Photometric

Performance

Reading Mode Transmittance(T), Absorbance(A), Concentration(C)
Photometric Range 0-125%, -0.1-3.00A
Static Baseline Drift (Cu) ≤0.004A/30 min ≤0.003A/30 min ≤0.002A/30 min
Dynamic Baseline Drift (Cu) ≤0.006A/15 min ≤0.005A/15 min ≤0.004A/15 min
Background Correction Deuterium (D2) Background Correction D2 and Self-absorption
Flame Analysis Characteristic Concentration Cu≤0.04ug/ml Cu≤0.035ug/ml Cu≤0.02ug/ml
Detection Limit Cu≤0.008ug/ml Cu≤0.006ug/ml Cu≤0.004ug/ml
Repeatability (Cu) RSD≤1% RSD≤0.6% RSD≤0.5%
Acetylene Flow Control Auto 12-level Auto 12-level Auto 12-level
Air Flow Control Auto 4-level Auto 4-level Auto 4-level
Nebulizer High efficiency glass
Burner Adjustment Automatic up and down
Burner Head Titanium alloy 100mm burner for air/acetylene operation
Premix Chamber Corrosion resistant
Safety Protection Flame sensor, gas leak sensor, gas pressure sensor
Data Processing Software RGWIN AAS software pacakage
Analytical Method Flame AA, Flame AE, Hydride Generation
Concentration Calculation

Method

Standard curve(6 linear/non-linear fitting), Standard Addition, Interpolation
Repeated Measurement Times 1-30 times, calculate the average, show SD and RSD value of absorbance and concentration
QA/QC Function Correlation coefficient, SD & RSD of Abs and calculate SD & RSD of concentration
Report Printing Parameter printing, resulting printing
Communication Port Standard RS-232
Others Computer External(excluded)
Dimension & Weight 850*650*550MM(W*D*H), 100Kg
Power Supply 110/220V, 50/60Hz
Working Environment Temperature 10 ~ 35 °C, Humidity≦85%

Packing List

NO. Description Qty NO. Description Qty
1 Main Unit 1 8 6mm air tube(transparent) 10m
2 Power Cable 1 9 USB(manual and software) 1
3 Data Cable 1 10 Drain Tube 2m
4 Screw Driver 1 11 Acetylene pressure reducing valve connector 1
5 Cu HCL 1 12 5A fuse 3
6 Air Compressor 1 13 Ignition filament 5
7 6mm acetylene tube(orange) 10m  
Shipping & Delivery

Standard Shipment

3 - 5 working days

IMPORTS

6 - 8 Weeks