The AA29 Series Flame AAS

R275,000.00Each

The AA29 Series Flame Atomic Absorption Spectrometer (AAS) introduces a modern, compact design tailored for today’s laboratories. With fully PC-controlled functionality.

SKU: HG_65943 Categories: ,
Description

The Advanced Features of the AA29 Series Flame AAS: A New Era in Elemental Analysis

Innovative Design and Configuration of the AA29 Series Flame AAS

The AA29 Series Flame Atomic Absorption Spectrometer (AAS) introduces a modern, compact design tailored for today’s laboratories. With fully PC-controlled functionality, the AA29 Series simplifies operation and data collection, allowing users to focus on obtaining accurate results. Its user-friendly interface enhances efficiency, making the analysis process more streamlined and less complex.

Key design features include:

  • Flexible configuration: Accommodates accessories to meet various analytical needs.
  • Application versatility: Suitable for petrochemistry, metallurgy, mining, geology, material analysis, food safety, and pharmacy.
  • Advanced optical system: Ensures stable readings and consistent results across a broad spectrum of analyses.

The AA29 Series provides precision and repeatability while minimizing interferences, setting a new benchmark in elemental analysis across scientific and industrial fields.

Key Safety Features and Performance Enhancements in the AA29 Series

The AA29 Series excels in safety and performance with several enhancements:

  1. Intelligent gas control module: Automatically adjusts gas flow and pressure, reducing risks and ensuring safe operations.
  2. Automatic pneumatic control: Regulates gas pressures for consistent, reliable results while adapting to various sample types.
  3. Total reflection optical system: Reduces energy loss, improving signal-to-noise ratio and sensitivity for detecting trace elements.

Additional safety measures include:

  • Deuterium lamp background correction: Minimizes reading interference.
  • Flame detection systems: Automatically shut down the device under unsafe conditions.
  • Pressure monitoring: Ensures safe operating parameters.

The modular design enables easy maintenance, reducing downtime, while the RGWIN AAS software simplifies operations, ensuring a seamless, high-performance user experience.

Flame AAS Specification

ModelAA2914AA2918AA2928
Optical SystemOptical TypeSingle beamSingle beamDouble beam
MonochromatorCzerny-Turner type with focal lengths at 350mm
Wavelength Range190-900nm
GratingHolographic diffraction grating with 1800 lines/mm
SlitsAutomated slit selection 0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm
Wavelength Accuracy±0.3 nm±0.2 nm±0.15 nm
Wavelength Repeatability±0.1nm±0.1nm±0.05nm
Lamp HolderAutomated 4-lamp turretAutomated 8-lamp turret
DetectorWide range UV sensitive photomultiplier tube
Photometric

Performance

Reading ModeTransmittance(T), Absorbance(A), Concentration(C)
Photometric Range0-125%, -0.1-3.00A
Static Baseline Drift (Cu)≤0.004A/30 min≤0.003A/30 min≤0.002A/30 min
Dynamic Baseline Drift (Cu)≤0.006A/15 min≤0.005A/15 min≤0.004A/15 min
Background CorrectionDeuterium (D2) Background CorrectionD2 and Self-absorption
Flame AnalysisCharacteristic ConcentrationCu≤0.04ug/mlCu≤0.035ug/mlCu≤0.02ug/ml
Detection LimitCu≤0.008ug/mlCu≤0.006ug/mlCu≤0.004ug/ml
Repeatability (Cu)RSD≤1%RSD≤0.6%RSD≤0.5%
Acetylene Flow ControlAuto 12-levelAuto 12-levelAuto 12-level
Air Flow ControlAuto 4-levelAuto 4-levelAuto 4-level
NebulizerHigh efficiency glass
Burner AdjustmentAutomatic up and down
Burner HeadTitanium alloy 100mm burner for air/acetylene operation
Premix ChamberCorrosion resistant
Safety ProtectionFlame sensor, gas leak sensor, gas pressure sensor
Data ProcessingSoftwareRGWIN AAS software pacakage
Analytical MethodFlame AA, Flame AE, Hydride Generation
Concentration Calculation

Method

Standard curve(6 linear/non-linear fitting), Standard Addition, Interpolation
Repeated Measurement Times1-30 times, calculate the average, show SD and RSD value of absorbance and concentration
QA/QC FunctionCorrelation coefficient, SD & RSD of Abs and calculate SD & RSD of concentration
Report PrintingParameter printing, resulting printing
Communication PortStandard RS-232
OthersComputerExternal(excluded)
Dimension & Weight850*650*550MM(W*D*H), 100Kg
Power Supply110/220V, 50/60Hz
Working EnvironmentTemperature 10 ~ 35 °C, Humidity≦85%

Packing List

NO.DescriptionQtyNO.DescriptionQty
1Main Unit186mm air tube(transparent)10m
2Power Cable19USB(manual and software)1
3Data Cable110Drain Tube2m
4Screw Driver111Acetylene pressure reducing valve connector1
5Cu HCL1125A fuse3
6Air Compressor113Ignition filament5
76mm acetylene tube(orange)10m 
Shipping & Delivery

Standard Shipment

3 - 5 working days

IMPORTS